What are the storage conditions for Polyethylene Glycol EG-4000/6000?

Answer
2026-05-17 官方文档 聚乙二醇PEG-4000/6000

Polyethylene Glycol PEG-4000/6000 should be stored in a cool (10-30°C), dry, well-ventilated environment, keeping the container sealed to prevent moisture absorption, and away from strong oxidizing agents.

Detailed Description

Polyethylene Glycol PEG-4000/6000 series are non-ionic high molecular polymers, appearing as white to slightly yellow waxy solids or flakes at room temperature. This product has strong hygroscopicity, readily absorbing moisture from the air, so the core of storage is moisture-proof sealing. Once damp, the product may clump and deteriorate, affecting its application effectiveness in pharmaceuticals, daily chemicals, textiles, and other fields.

In terms of temperature control, it is recommended to maintain the warehouse temperature within the 10-30°C room temperature range. Although PEG-4000/6000 have relatively high melting points (typically between 54-63°C), prolonged exposure to high temperatures may cause the product to darken in color and broaden the molecular weight distribution. Also, avoid excessive hardening due to too low temperature, which generally does not affect the intrinsic quality of the product.

Safety aspects require special attention: When fine dust of PEG-4000/6000 mixes with air to a certain concentration, it may form an explosive mixture (dust explosion class St1). Therefore, the storage area must be away from open flames, sparks, and hot surfaces. All equipment should be grounded to prevent static electricity accumulation.

Storage Condition Parameters

Storage ParameterSpecific Requirement
Temperature RangeRecommended 10-30°C (cool room temperature environment)
Humidity RequirementDry environment, strictly moisture-proof
Ventilation ConditionWell-ventilated warehouse
Packaging SealContainer must be sealed
Incompatible MaterialsKeep away from strong oxidizing agents (peroxides, potassium permanganate, concentrated nitric acid, etc.)
Dust Explosion ClassSt1, minimum ignition temperature of dust cloud > 400°C
Flash Point (Open Cup)> 240°C
Stacking RequirementsFollow local safety regulations to prevent tipping and damage to packaging

Application Recommendations

To ensure the product remains in optimal condition before use, it is recommended to follow the "First In, First Out" inventory management principle. Unused product after opening should be resealed immediately to avoid prolonged exposure to air. For customers storing in large quantities, consider equipping dehumidifiers or desiccants to further reduce warehouse humidity.

Precautions

  • No Open Flames: The storage area should have clear "No Fire" signs, and electrical equipment must meet explosion-proof requirements.
  • Anti-static Measures: All metal containers and equipment must be reliably grounded, and operators should wear anti-static work clothes and shoes.
  • Avoid Dust Generation: Handle gently during handling and material retrieval to avoid creating dust clouds. It is recommended to equip appropriate dust collection systems.
  • Emergency Preparedness: Water mist, dry powder, or carbon dioxide fire extinguishers should be available near the storage area. Avoid using direct water jets on accumulated dust.
  • Hygroscopicity Warning: If the product has been severely dampened and clumped, evaluate whether it is still suitable for its intended use, and perform quality testing if necessary before use.