Isotridecyl alcohol phosphate ester E-1306P belongs to the acidic anionic phosphate ester surfactant category. Although its chemical properties are relatively stable, improper storage conditions may still lead to quality deterioration. To ensure product performance and safe use, the following storage requirements must be strictly followed: The storage site should be a dedicated warehouse or container area that is cool, dry, and well-ventilated, avoiding outdoor stacking. Containers must always be kept tightly sealed to prevent moisture ingress and contamination, while also reducing the potential impact of vapor emissions on the environment.
This product should be kept away from heat sources, sparks, and open flames, and should not be stored together with strong oxidizers, strong alkalis, or other incompatible substances to prevent hazardous reactions. Use corrosion-resistant, well-sealed containers for storage. Recommended materials include stainless steel and polyethylene. It is particularly important to note that empty containers may contain residual hazardous substances and must not be used for storing food or drinking water.
| Storage Parameter | Specific Requirement |
|---|---|
| Storage Environment | Cool, dry, well-ventilated dedicated warehouse or container area |
| Temperature Range | 5°C – 40°C, prevent freezing and high-temperature degradation |
| Container Condition | Keep sealed, use corrosion-resistant and well-sealed containers |
| Recommended Material | Corrosion-resistant materials such as stainless steel, polyethylene |
| Sources to Avoid | Heat sources, sparks, open flames, strong oxidizers, strong alkalis |
| Prohibitions | Empty containers must not be used for food storage; do not mix with incompatible substances |
In practical operation, it is recommended to establish a dedicated storage management log and regularly check container integrity and appearance. If the product exhibits increased viscosity or slight turbidity in low-temperature winter environments, this is a normal physical phenomenon. Before use, gentle warming within the recommended storage temperature range is allowed, but direct heating is strictly prohibited. For products stored long-term, it is recommended to perform a small-sample test before initial use to confirm that key performance indicators (such as pH value, lubricity, etc.) have not changed significantly before batch use.